Miniflow

The Miniflow is used for blowing in fibre optic cables from 5 up to 8 mm into ducts from 7up to 16 mm. The Miniflow has a robust and compact design and is very simple to operate. The drive chains are propelled by two low-wear and low-noise hydraulic motors which enable for- and backward movement of the cable.

 

Technical Data:  
max. speed:  80 m/min
required air flow: 1 m³/min
required air pressure: 15 bar
Control unit and Power Pack  (125 bar / 15 l/min) essential
Order No.  111.301.00

Especially for thinner cables there is a danger of compression. The manometer at the afloat bedded blowing junction unit indicates sequentially the rise of the friction forces between pipe and cable what enables an immediate reaction with increasing the aerial amount or a reducing the pushing speed.

Please use categorical Bagela lube B 50, Order No. 111.340.00

Spare and wear parts

Chain rail (front) Order No. 111.315.01

The chain rail supports the drive chain and is mounted completely with chain wheel and holder. It is recommended to change the rear and the front rail at the same time.

Chain rail (rear) Order No. 111.315.02

The chain rail supports the drive chain and is mounted completely with chain wheel and holder. It is recommended to change the rear and the front rail at the same time.

Wear rail for Chain rail Order No. 111.315.03

for chain rail

Drive chain Order No. 111315.00

The drive unit consists of two conveyor chains and is provided with special rubber profile. The drive chains pull the cable into the Miniflow. It is recommended to change the two drive chains at the same time.

Odometer Order No. 111.330.00

The measuring instrument is integrated in the Miniflow. It simplifies the monitoring of the injected length. The measuring instrument has a maximum measurement of 99999.9 m.

Nylon applicator Order No. 111.334.00

The applicator leads the cable directly into the Miniflow

Insert

The insert is available in different sizes and has to be reconciled to the actual size of the cable and the duct. Please specify the outer duct size.

Order No. Cable dia. mm
111.335.00 10
111.336.00 12
111.337.00 14
111.338.00 16

Cable sealing ring

At least 2 pieces are necessary!

Order No. Cable dia. mm
111.318.00 4.0
111.319.00 4.5
111.320.00 5.0
111.321.00 5.5
111.326.00 8.0

Afterblow adapter for mini cable Order No. 111.341.00

With the loops can be reduced down to approx. 70 mm. This rest could be carefully inserted into the micro pipe and the pipe ends connected with a bushing.

Data Sheet Miniflow PDF-file