Gerneral view Blowing-in machines

Powerflow Order No. 111.200.00

A true power pack to insert LWL cable with a diameter of 8-22mm into pipes with a diameter of 32-50 mm.

Technical Data:  
max. speed: 80 m/min
required air flow 10 m³/min
requiredair pressure: 12 bar
Control unit and power pack: (125 bar / 15 l/min) essential!



Multiflow Order No. 111.250.00

Designed to blow in multiple micro ducts or single large size cables into ducts with a dia. of 32 up to 50 mm. It is suitable for air- and water blowing. The drive chains are propelled by two low-wear and low-noise hydraulic motors.

Technical Data:  
max.speed: 50 m/min
reuired air flow: 10 m³/min
reuired air pressure: 12 bar
Control unit and power pack: (125 bar / 15 l/min)essential!

MiniflowOrder No. 111.301.00

Miniflow is used for blowing in fibre optic cables from 4 up to 11 mm into ducts from 10 up to 16 mm.

Technical Data:  
max. speed: 80 m/min
required air flow:: 1 m³/min
required air pressure: 15 bar
Control unit and power pack: (125 bar / 15 l/min) essential

Microflow Order No. 111.350.00

Microflow is used for blowing in small fibre optic cable 1- 4 mm. in pipes of outer dia. 5, 7 or 10 mm.

Technical Data:  
max. speed: 100 m/min
required air flow: 1 m³/min
required air pressure: 15 bar
required electric power supply 230 V
rating 180 W

Hydraulic Power Pack BHA 125/15 Order No. 010.120.00

The Power Pack is required for Bagela Powerflow, Multiflow und Miniflow.

Technical Data:  
Hydraulic pressure: 125 bar
Flow rate: 15 l/min
Weight: 84 kg

Hydraulic hose 10 m for BHA 125/15 Order No. 003.528.02

Hydraulic Control Unit Order No. 111.420.00

With the control unit pressure and speed are regulated. The chains of the particular injection system are set in motion by the lever. The Power Pack is required for Bagela Powerflow, Multiflow und Miniflow.

Compressor Order No. 111.430.00

suitable for Miniflow and Microflow, an air cooler is necessary

Mobilair M17/15  
Air pressure max. 15 bar
Air flow 1 m³/min

Water Pump Order No. 111.410.00

The high-pressure water aggregate can optionally be used for Powerflow as well as for Multiflow.

Data Sheet General View Blowing-in Machines PDF-file

General View Blowing-in Machines (557.2 KiB)

Go back